Symedria.com

DarkLight
GB / EN
United Kingdom
EN (default)
🇩🇪 Germany
🇩🇪DE (default)
🇵🇱 Poland
🇵🇱PL (default)

Wishlist

Nothing saved yet

Tap the heart on a product to keep it here.

Browse the catalogue

Account

customer

Your cart

Your cart is empty

Browse catalogue

Not delivered to {country}

Similar products from this category

Add

Subtotal

Delivery

Total

incl. VAT {rate}

None of these items can be delivered to this country

HomeAll categories

Account

Help & information

DarkLight
GB / EN
United Kingdom
EN (default)
🇩🇪 Germany
🇩🇪DE (default)
🇵🇱 Poland
🇵🇱PL (default)

Search…

Products

Categories

Properties

Nothing found

default

Technoflux dental

SKU

ESN004060

ELITE101 UVC air treatment unit with external lamp, counter and programmer

Dual-action UVC air treatment unit for rooms up to 30 m²: internal chamber treatment while people are present, plus a direct external lamp for unoccupied rooms, with counter and programmer.

£696.99
£580.83excl. VAT

Original price

you save

Delivery3–5 days
Order before18:00:00
Returns14 days
Free shipping over83.58 GBP

Key specifications

Filter change time

every 1000 h of use

Warranty period

1 year

Radiator type

PHILIPS TUV

Radiator usage time

9000 h / min. 1 year

All specifications →
With people in the room, the air is drawn through the device and sterilized inside a closed chamber, so external UVC emission is limited to the enclosed chamber. When the room is empty, a direct-action external lamp illuminates the space; the two systems can also work together. Air enters through the inlet past an ANTY-DUST filter, which blocks larger particles and keeps the reflectors of the germicidal lamp clean. The airflow then passes a low-pressure mercury PHILIPS TUV lamp emitting UVC at 253.7 nm; the mirrored chamber concentrates the radiation, and treated air leaves through the end nozzle. The unit is powered from 230V / 50Hz, covers up to 30 m² and runs at a noise level of 40 dB. The radiator is rated for 9000 h or at least 1 year of use, the filter change time is 1000 hours, safety class is IP 20, and the warranty period is 1 year. A counter and programmer are part of the model.
Filter change timeevery 1000 h of use
Warranty period1 year
Radiator typePHILIPS TUV
Radiator usage time9000 h / min. 1 year
Safety classIP 20
Technoflux dentalTechnoflux dental
Noise Level40
Coversup to 30 m2
Power230V / 50Hz
Wavelength253.7 nm
reviews
ELITE101 UVC air treatment unit with external lamp, counter and programmer

ELITE101 UVC air treatment unit with external lamp, counter and programmer

£696.99
£580.83excl. VAT

Original price

you save

Why the ELITE 101 works for busy rooms

Protected with people in the room
While the room is occupied, air treatment happens inside the device chamber, so external UVC emission is confined to the enclosed chamber.
External lamp for empty rooms
One or two additional direct-action external lamps illuminate the room when nobody is present, and both systems can run at the same time.
Filtered, reflected, sterilized
Filtered, reflected, treated
Counter and programmer
The model includes a counter and programmer, and the radiator and filter have their own service intervals to plan around.

How the air is treated

Air is drawn in
The internal ventilation system pulls room air into the sterilizer chamber.
Particles are blocked
The ANTY-DUST filter at the inlet catches larger particles before the lamp.
UVC exposure
Air passes the low-pressure mercury lamp emitting at 253.7 nm, with rays concentrated by the mirrors.
Clean air returns
Treated air is released through the end nozzle.

ELITE 101 at a glance

30 m²
Room area covered
253.7 nm
UVC wavelength emitted by the lamp
9000 h
Radiator usage time, minimum 1 year

What is inside the air path

ANTY-DUST filter
Sits near the inlet and blocks larger particles so the germicidal lamp reflectors stay clean.
PHILIPS TUV radiator
Low-pressure mercury lamp emitting UVC at 253.7 nm as the air passes directly through it.
Mirrored chamber
High reflection coefficient concentrates the UVC rays and supports the radiation interaction.
End nozzle
Releases the treated air back into the room.
External direct lamp
One or two additional lamps that illuminate the room when it is unoccupied.
Counter and programmer
Controls built into this model to manage operation and lamp use.

Designed around safe use

External UVC emission reduced to zero during occupied operation
Internal and external systems can operate at the same time
Counter and programmer included in the model
IP 20 safety class

ELITE 101 in view

The ELITE 101 unit

The ELITE 101 unit

The sterilizer housing with its inlet and end nozzle, the point where treated air returns to the room, and one or two external direct lamps for unoccupied rooms.

Questions about the ELITE 101

Can the device be used while people are in the room?
While the room is occupied, air treatment takes place inside the device chamber, and external UVC emission is confined to the enclosed chamber.
Can both disinfection systems work together?
Yes. The internal chamber system and the external direct lamp can operate at the same time; refer to the manufacturer's instructions for intended use.
How much room can it cover?
The ELITE 101 covers up to 30 m² according to the product data.
What maintenance should I plan for?
The radiator usage time is 9000 h or a minimum of 1 year, the filter change time is 1000 hours, and the unit carries a 1 year warranty period.
What lamp and wavelength does it use?
It uses a PHILIPS TUV radiator, a low-pressure mercury lamp emitting UVC at 253.7 nm, powered from 230V / 50Hz.

Enquire about the ELITE 101

Questions about this product?
Leave your name and phone number and we will call you back.

Purpose: answering your enquiry about this product. Legal basis: your consent. You may withdraw it at any time.

ELITE101 UVC air treatment unit with external lamp, counter and programmer

ELITE101 UVC air treatment unit with external lamp, counter and programmer

£696.99
£580.83excl. VAT

Original price

you save